STEUER14

U15A700 External GPS source, Missing message

Set by the PCM / MIB3 – Information Control Unit and MIB3 (Zentralrechner) on the Porsche Taycan and Panamera (972). Also written U15A7.

Which models and control units set U15A700

Control unitModelsFault level
PCM / MIB3 – Information Control UnitLevel 6 · General note
MIB3 (Zentralrechner)Level 6 · General note

Possible causes of U15A700

From the factory guided fault finding when the PCM / MIB3 – Information Control Unit sets this code (Taycan):

  • Control unit – external communication – Defective: Connectors
  • Lines – Defective: Ground line to Connect control unit
  • Lines – Defective: Power supply for Connect control unit
  • Control unit – external communication – Faulty
  • Lines – CAN-Bus Connect – defective

STEUER14 walks you through the factory guided test for U15A700 on the car: 8 checks in the right order, down to the faulty part. How guided fault finding works

How to read and clear U15A700

Run a fault scan in STEUER14 over a standard ENET cable: U15A700 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the PCM / MIB3 – Information Control Unit

CodeFault
U13F300Connection for external media source, rear - no communication
U140000Function restriction – supply voltage too low
U140100Function restriction – supply voltage too high
U142100Connect control unit - no communication
U142B00Ethernet databus, Open circuit
U143400Ethernet databus, Short circuit

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.