STEUER14

U150600 LIN bus 5 - no communication

Set by the Air Conditioning, BCM1 – Central Electrics and 1 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written U1506.

Which models and control units set U150600

Control unitModelsFault level
Air ConditioningLevel 6 · General note
BCM1 – Central ElectricsLevel 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
BCM1 (Body Control Module 1)Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)

Possible causes of U150600

From the factory guided fault finding, by the control unit that sets the code:

Air Conditioning (Taycan, Panamera (971) and Cayenne)

  • Air-conditioning control unit – faulty
  • Fuse – Burnt through
  • Fuse – Incorrect part
  • Seat ventilation control unit – faulty: Control unit for rear left seat heating
  • Seat ventilation control unit – faulty: Control unit for rear right seat heating

BCM1 – Central Electrics (Taycan, 911 (992), Panamera (971) and Cayenne)

  • Fuse – faulty: Fuse box in front left footwell, row C, fuse F8
  • Fuse – faulty: Fuse box in front right footwell, row F, fuse F12
  • Fuse – Faulty: Fuse box in front left footwell, row B, fuse F8
  • Fuse – Faulty
  • Gateway control unit – Check fault memory

…and 30 more in the guided test.

STEUER14 walks you through the factory guided test for U150600 on the car, down to the faulty part. How guided fault finding works

How to read and clear U150600

Run a fault scan in STEUER14 over a standard ENET cable: U150600 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the Air Conditioning

CodeFault
U132A00Front sun sensor - no communication
U133800Servo motor for rear left air distribution - no communication
U134400Servo motor for center front left horizontal air vent – no communication
U134600Servo motor for center front left vertical air vent – no communication
U140000Function restriction – supply voltage too low
U140100Function restriction – supply voltage too high

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.