STEUER14

U12D000 IPv6 address conflict

Set by the DC/DC Converter, Gateway and 7 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written U12D0.

Which models and control units set U12D000

Control unitModelsFault level
DC/DC ConverterLevel 4 · Fault
GatewayLevel 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
PCM / MIB3 – Information Control UnitLevel 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
OTA Function Control UnitLevel 4 · Fault
Telematics Communication UnitLevel 6 · General note
PCM / MIB2 – Information Control UnitLevel 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
Rear Axle Steering 2Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
MIB3 (Zentralrechner)Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
MIB2 (Zentralrechner)Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)

Possible causes of U12D000

From the factory guided fault finding, by the control unit that sets the code:

PCM / MIB3 – Information Control Unit (Taycan)

  • Central computer PCM 4.1 – Faulty

OTA Function Control Unit (Taycan)

  • Over-the-air control unit – Faulty: Over-the-air control unit faulty
  • Over-the-air control unit – Incorrect software: Incorrect software

Telematics Communication Unit (Taycan and 911 (992))

  • Control unit – external communication – Faulty

STEUER14 walks you through the factory guided test for U12D000 on the car, down to the faulty part. How guided fault finding works

How to read and clear U12D000

Run a fault scan in STEUER14 over a standard ENET cable: U12D000 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the DC/DC Converter

CodeFault
U11BC00Ethernet databus branch 2, Electrical error
U122C00Ethernet databus branch 1, No communication
U122D00Ethernet databus branch 2, No communication
U12C900MAC address conflict in Ethernet switch branch 2
U140000Function restriction – supply voltage too low
U140100Function restriction – supply voltage too high

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.