U12D000 IPv6 address conflict
Set by the DC/DC Converter, Gateway and 7 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written U12D0.
Which models and control units set U12D000
| Control unit | Models | Fault level |
|---|---|---|
| DC/DC Converter | Taycan | Level 4 · Fault |
| Gateway | Taycan911 (992)Panamera (971)Panamera (972)Cayenne | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| PCM / MIB3 – Information Control Unit | Taycan | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| OTA Function Control Unit | Taycan | Level 4 · Fault |
| Telematics Communication Unit | Taycan911 (992)Panamera (971)Panamera (972)Cayenne | Level 6 · General note |
| PCM / MIB2 – Information Control Unit | 911 (992)Panamera (971) | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| Rear Axle Steering 2 | 911 (992) | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| MIB3 (Zentralrechner) | Panamera (972) | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| MIB2 (Zentralrechner) | Cayenne | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
Possible causes of U12D000
From the factory guided fault finding, by the control unit that sets the code:
PCM / MIB3 – Information Control Unit (Taycan)
- Central computer PCM 4.1 – Faulty
OTA Function Control Unit (Taycan)
- Over-the-air control unit – Faulty: Over-the-air control unit faulty
- Over-the-air control unit – Incorrect software: Incorrect software
Telematics Communication Unit (Taycan and 911 (992))
- Control unit – external communication – Faulty
STEUER14 walks you through the factory guided test for U12D000 on the car, down to the faulty part. How guided fault finding works
How to read and clear U12D000
Run a fault scan in STEUER14 over a standard ENET cable: U12D000 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the DC/DC Converter
| Code | Fault |
|---|---|
| U11BC00 | Ethernet databus branch 2, Electrical error |
| U122C00 | Ethernet databus branch 1, No communication |
| U122D00 | Ethernet databus branch 2, No communication |
| U12C900 | MAC address conflict in Ethernet switch branch 2 |
| U140000 | Function restriction – supply voltage too low |
| U140100 | Function restriction – supply voltage too high |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.