U11DB00 Control module for automatized in-phase control, No communication
Set by the Gateway on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written U11DB.
Which models and control units set U11DB00
| Control unit | Models | Fault level |
|---|---|---|
| Gateway | Taycan911 (992)Panamera (971)Panamera (972)Cayenne | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
Possible causes of U11DB00
From the factory guided fault finding when the Gateway sets this code (Taycan, 911 (992), Panamera (971) and Cayenne):
- Gateway control unit – Check fault memory
- Lines – Defective: Power supply for route detection control unit
- Lines – Defective: Ground line to route detection control unit
- Route detection control unit – Control unit faulty
- Lines – Defective: Flexray of route detection control unit
- Central control unit for assistance systems – Control unit faulty
STEUER14 walks you through the factory guided test for U11DB00 on the car: 12 checks in the right order, down to the faulty part. How guided fault finding works
How to read and clear U11DB00
Run a fault scan in STEUER14 over a standard ENET cable: U11DB00 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the Gateway
| Code | Fault |
|---|---|
| U11C400 | Ethernet databus, No communication |
| U11DC00 | Charging module, contactless high-voltage charging (AWC) - missing message |
| U11DD00 | Display and operator control unit - no communication |
| U11E300 | FlexRay data bus channel B branch 9 faulty |
| U11E400 | FlexRay data bus channel B branch 10 faulty |
| U11E600 | FlexRay data bus channel B branch 12 faulty |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.