STEUER14

P2B6500 Additional coolant pump (P5) – dry run

Set by the Thermal Management, DME – Engine Control Unit and 2 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P2B65.

Which models and control units set P2B6500

Control unitModelsFault levelWarning lamp
Thermal ManagementLevel 2 · Fault that needs a workshop visit nowWarning lamp on
DME – Engine Control UnitLevel 2 · Fault that needs a workshop visit now–
Engine Control Module 1Level 2 · Fault that needs a workshop visit now–
TME (Thermomanagement)Level 2 · Fault that needs a workshop visit nowWarning lamp on

Possible causes of P2B6500

From the factory guided fault finding, by the control unit that sets the code:

DME – Engine Control Unit (Panamera (971) and Cayenne)

  • Cooling system – too little coolant in cooling system
  • Cooling system – Air in system
  • Cooling system – Leak

Thermal Management (Panamera (971) and Cayenne)

  • Add. coolant pump, high-temperature – Defective: Pump P5
  • Cooling system – Too little medium/material
  • Cooling system – blocked: High-temperature heating circuit
  • Cooling system – Air in system: High-temperature heating circuit

STEUER14 walks you through the factory guided test for P2B6500 on the car, down to the faulty part. How guided fault finding works

How to read and clear P2B6500

Run a fault scan in STEUER14 over a standard ENET cable: P2B6500 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the Thermal Management

CodeFault
P2B2A00Coolant pump (P1) – dry run
P2B3000Right radiator fan (RF1) – blocked
P2B3200Left radiator fan (RF3) – blocked
P2C7200Medium-temperature circuit for drive, rear – cooling power too low
P2D3800Low-temperature circuit for high-voltage battery – heating performance too low
U002800Hybrid CAN bus – faulty

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.