P1CA500 Change-over valve for medium-temperature circuit (UVW2, MVW4), mechanical error
Set by the Thermal Management and TME (Thermomanagement) on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P1CA5.
Which models and control units set P1CA500
| Control unit | Models | Fault level |
|---|---|---|
| Thermal Management | Taycan911 (992)Panamera (971) | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
| TME (Thermomanagement) | Panamera (972)Cayenne | Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current) |
Possible causes of P1CA500
From the factory guided fault finding when the TME (Thermomanagement) sets this code (Cayenne):
- Change-over valve: Change-over valve for low-temperature circuit upstream of radiator, UVW2
- Cooling air flaps – Faulty: Middle radiator
- Change-over valve – Faulty: Switchover valve for low-temperature circuit upstream of cooler, UVW2
- Coolant – Foreign bodies
- Temperature sender – Connectors interchanged: Temperature sensor for low-temperature circuit TW5 interchanged with TW6 (Cayenne)
STEUER14 walks you through the factory guided test for P1CA500 on the car: 11 checks in the right order, down to the faulty part. How guided fault finding works
How to read and clear P1CA500
Run a fault scan in STEUER14 over a standard ENET cable: P1CA500 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the Thermal Management
| Code | Fault |
|---|---|
| P1C5E00 | Refrigerant circuit sensor on low pressure side (PT3) - signal implausible |
| P1C5F00 | Refrigerant circuit sensor on low pressure side (PT3) – fault |
| P1CA300 | Medium-temperature circuit for drive, front – cooling performance too low |
| P1CDF00 | Refrigerant circuit sensor on low pressure side (PT3) – temperature signal deviation too high |
| P218300 | Temperature sensor for high-temperature circuit (TW11) – signal implausible |
| P218500 | Temperature sensor for high-temperature circuit (TW11) – short circuit to B+ |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.