P19FB00 Directional-control valve for high-temperature circuit (MVW1) – mechanical fault
Set by the Thermal Management and TME (Thermomanagement) on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P19FB.
Which models and control units set P19FB00
| Control unit | Models | Fault level | Warning lamp |
|---|---|---|---|
| Thermal Management | Taycan911 (992)Panamera (971) | Level 2 · Fault that needs a workshop visit now | Warning lamp on |
| TME (Thermomanagement) | Panamera (972)Cayenne | Level 2 · Fault that needs a workshop visit now | Warning lamp on |
Possible causes of P19FB00
From the factory guided fault finding when the Thermal Management sets this code (Taycan):
- Directional-control valve – faulty: Directional-control valve for high-temperature circuit MVW1
- Coolant – Too little medium/material
- Coolant – Foreign bodies
STEUER14 walks you through the factory guided test for P19FB00 on the car: 8 checks in the right order, down to the faulty part. How guided fault finding works
How to read and clear P19FB00
Run a fault scan in STEUER14 over a standard ENET cable: P19FB00 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the Thermal Management
| Code | Fault |
|---|---|
| P10DC00 | Refrigerant circuit sensor on low pressure side (PT2) – part number implausible |
| P10E800 | Bleed cooling systems function – active |
| P139C00 | Coolant level sensor (LS2) – coolant level too low |
| P175700 | Power supply (terminal 30) – open circuit |
| P1A3E00 | Directional-control valve for medium-temperature circuit (MVW2) – mechanical fault |
| P1A4700 | Change-over valve for low-temperature circuit (UVW4, MVW3), mechanical error |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.