STEUER14

P0CD700 Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output), short circuit to ground

Set by the Battery Energy Control Module, Thermal Management and 1 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P0CD7.

Which models and control units set P0CD700

Control unitModelsFault levelWarning lamp
Battery Energy Control ModuleLevel 6 · Note–
Thermal ManagementLevel 2 · Fault that needs a workshop visit nowWarning lamp on
Battery Energy Control ModuleLevel 2–
Battery Energy Control ModuleLevel 2 · Fault that needs a workshop visit now–
TME (Thermomanagement)Level 2 · Fault that needs a workshop visit nowWarning lamp on

Possible causes of P0CD700

From the factory guided fault finding when the Thermal Management sets this code (Taycan, Panamera (971) and Cayenne):

  • Temperature sender – Faulty: Temperature sensor for low-temperature circuit, TW8
  • Thermal management control unit – Faulty
  • Main wire harness – faulty: Signal line
  • Main wire harness – faulty: Ground line

STEUER14 walks you through the factory guided test for P0CD700 on the car: 8 checks in the right order, down to the faulty part. How guided fault finding works

How to read and clear P0CD700

Run a fault scan in STEUER14 over a standard ENET cable: P0CD700 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the Battery Energy Control Module

CodeFault
P0C4C00Additional coolant pump in low-temperature circuit (P2) – short circuit to ground
P0CA600High-voltage battery – charging current too high
P0CA700Hybrid Battery Discharging Current High
P0CD600Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output) – signal implausible
P0DAB00SPI bus - no communication
P0DAC00Hybrid/EV Battery Cell Balancing Circuit "A"

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.