P0C4C00 Additional coolant pump in low-temperature circuit (P2) – short circuit to ground
Set by the Battery Energy Control Module on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P0C4C.
Which models and control units set P0C4C00
| Control unit | Models | Fault level |
|---|---|---|
| Battery Energy Control Module | Taycan | Level 4 · Fault |
| Battery Energy Control Module | 911 (992) | Level 2 |
| Battery Energy Control Module | Panamera (971)Panamera (972)Cayenne | Level 2 · Fault that needs a workshop visit now |
Possible causes of P0C4C00
From the factory guided fault finding when the Battery Energy Control Module sets this code (Panamera (971) and Cayenne):
- Relay – faulty: Coolant pump for high-voltage battery
- Relay carrier 1 – Scorched
- Relay carrier 1 – Incorrectly connected, reversed
- Relay carrier 1 – Plug connections corroded
- Relay carrier 1 – Loose contact, contact fault
- High-voltage battery control unit – faulty
STEUER14 walks you through the factory guided test for P0C4C00 on the car, down to the faulty part. How guided fault finding works
How to read and clear P0C4C00
Run a fault scan in STEUER14 over a standard ENET cable: P0C4C00 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the Battery Energy Control Module
| Code | Fault |
|---|---|
| P0C4700 | Additional coolant pump in low-temperature circuit (P2) – no communication |
| P0C4800 | Additional coolant pump in low-temperature circuit (P2) – PWM signal, short circuit to ground |
| P0C4900 | Additional coolant pump in low-temperature circuit (P2) – PWM signal, short circuit to B+ |
| P0C4A00 | Auxiliary coolant pump in the low-temperature circuit (P2) – error |
| P0CA600 | High-voltage battery – charging current too high |
| P0CA700 | Hybrid Battery Discharging Current High |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.