P05A600 Servo motor for cooling-air flaps, right (SM1) – supply voltage implausible
Set by the Thermal Management and TME (Thermomanagement) on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne. Also written P05A6.
Which models and control units set P05A600
| Control unit | Models | Fault level | Warning lamp |
|---|---|---|---|
| Thermal Management | Taycan911 (992)Panamera (971) | Level 2 · Fault that needs a workshop visit now | Warning lamp on |
| TME (Thermomanagement) | Panamera (972)Cayenne | Level 2 · Fault that needs a workshop visit now | Warning lamp on |
Possible causes of P05A600
From the factory guided fault finding when the Thermal Management sets this code (Taycan, Panamera (971) and Cayenne):
- Main wire harness – faulty: B+ line
- Main wire harness – faulty: Ground line
- Cooling air flaps – faulty: Servo motor for radiator shutter
STEUER14 walks you through the factory guided test for P05A600 on the car: 8 checks in the right order, down to the faulty part. How guided fault finding works
How to read and clear P05A600
Run a fault scan in STEUER14 over a standard ENET cable: P05A600 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual
Other codes of the Thermal Management
| Code | Fault |
|---|---|
| P056200 | Supply voltage - voltage too low |
| P056300 | Supply voltage too high |
| P059B00 | Servo motor for cooling-air flaps, right (SM1) – position implausible |
| P05A000 | Servo motor for cooling-air flaps, right (SM1) – mechanical fault |
| P05AA00 | Servo motor for cooling-air flaps, left (SM2) – position implausible |
| P05AF00 | Servo motor for cooling-air flaps, left (SM2) – mechanical fault |
Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.