STEUER14

B182D16 Electric interior heater (Z189) - 800V electronics, voltage too low

Set by the Thermal Management and TME (Thermomanagement) on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne.

Which models and control units set B182D16

Control unitModelsFault levelWarning lamp
Thermal ManagementLevel 2 · Fault that needs a workshop visit nowWarning lamp on
TME (Thermomanagement)Level 2 · Fault that needs a workshop visit nowWarning lamp on

Possible causes of B182D16

From the factory guided fault finding when the Thermal Management sets this code (Taycan):

  • Lines – High-voltage power supply – defective: Positive and ground line

STEUER14 walks you through the factory guided test for B182D16 on the car: 8 checks in the right order, down to the faulty part. How guided fault finding works

How to read and clear B182D16

Run a fault scan in STEUER14 over a standard ENET cable: B182D16 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the Thermal Management

CodeFault
B16A285Refrigerant circuit for passenger compartment cooling – pressure too high
B182C04Electric interior heater (Z189), internal error
B182C92Electric interior heater (Z189), internal error
B184C00Release active
B200500Coding
B201200Coding

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.