B151804 Control unit for chassis control (in instrument cluster) – faulty

Set by the BCM1 – Central Electrics, Front Operating Unit and 2 more on the Porsche Taycan, 911 (992), Panamera (971), Panamera (972) and Cayenne.

Which models and control units set B151804

Control unitModelsFault level
BCM1 – Central ElectricsLevel 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)
Front Operating UnitLevel 6 · Note
BedienSG_vo (Bedieneinheit vorne)Level 6 · Note
BCM1 (Body Control Module 1)Level 4 · Fault that leads to advice before driving off; availability may be limited (e.g. higher quiescent current)

Possible causes of B151804

From the factory guided fault finding when the Front Operating Unit sets this code (911 (992)):

  • Operator control unit in front centre console – faulty: Operating / A/C unit, front centre console

STEUER14 walks you through the factory guided test for B151804 on the car: 5 checks in the right order, down to the faulty part. How guided fault finding works

How to read and clear B151804

Run a fault scan in STEUER14 over a standard ENET cable: B151804 shows with its status and freeze frame. Reading and clearing fault codes is free. More about fault memory in the manual

Other codes of the BCM1 – Central Electrics

CodeFault
B14CD56Front right seat backrest fan, part number implausible
B14CF31Front right seat cushion fan – no communication
B14CF56Front right seat cushion fan – part number implausible
B14EE01Left rear reading lamp, Electrical error
B14EF01Right rear reading lamp, Electrical error
B154216ParkAssist – supply voltage too low

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code says what a control unit detected, not always which part failed.