Thermal Management: fault codes
All 636 fault codes of the Porsche Taycan Thermal Management with the manufacturer's names. How to read and clear them with STEUER14.
All 636 fault codes
The same fault codes apply to: Thermal Management on the 911 (992) and TME (Thermomanagement) on the Cayenne.
| Code | Fault |
|---|---|
| B109E13 | A/C compressor run-in - open circuit |
| B109E85 | A/C compressor run-in - refrigerant pressure difference too low |
| B109EF0 | Electric air-conditioning compressor (V470), not taught |
| B109F21 | A/C compressor run-in, compressor speed - below lower limit value |
| B109F22 | A/C compressor run-in, compressor speed - above upper limit value |
| B10ABF0 | Refrigerant circuit – pressure too low |
| B10ACF0 | Refrigerant circuit – pressure too high |
| B10AE04 | Refrigerant circuit sensor on high pressure side (PT1) – fault |
| B10AE31 | Refrigerant circuit sensor on high pressure side (PT1) – no communication |
| B10C222 | Refrigerant circuit – temperature too high |
| B10C2F0 | Sensor for refrigerant pressure and temperature, Sensor 3 interchanged with sensor 4 |
| B10CD00 | Function restriction due to energy management |
| B10D004 | Coolant pump - mechanical fault |
| B10D031 | Coolant pump - no signal |
| B10D098 | Coolant pump - temperature too high |
| B10D0F0 | Coolant pump - dry run |
| B138100 | Function restriction due to energy management |
| B139700 | Function restriction, crash signal |
| B145316 | Electric A/C compressor – function restriction due to undervoltage |
| B145317 | Electric A/C compressor – function restriction due to overvoltage |
| B14534B | Electric A/C compressor – function restriction due to overtemperature protection |
| B1453F0 | Electric air-conditioning compressor (V470) - motor, high-voltage supply error |
| B1453F1 | Electric A/C compressor – power output fault |
| B1453F2 | Electric air-conditioning compressor (V470), temperature shutdown |
| B1453F3 | Electric air-conditioning compressor (V470) – overload protection active |
| B148421 | LIN bus 1 – not taught |
| B148422 | LIN bus 1 – not taught |
| B148521 | LIN bus 2 – not taught |
| B148522 | LIN bus 2 – not taught |
| B158011 | Refrigerant cut-off valve 2, Short circuit to ground |
| B158012 | Shut-off valve 2 for refrigerant, Short circuit to B+ |
| B158013 | Shut-off valve 2 for refrigerant, Open circuit |
| B158104 | Electric interior heater (Z189), faulty |
| B158116 | Electric interior heater – voltage too low |
| B158117 | Electric interior heater – voltage too high |
| B158129 | Electric interior heater – signal implausible |
| B158131 | Electric interior heater – no communication |
| B15814A | Electric interior heater – part number implausible |
| B158192 | Electric interior heater – fault |
| B158198 | Electric interior heater, 12 V electronics – temperature too high |
| B1581F0 | Electric interior heater – temperature 1 too high |
| B1581F1 | Electric interior heater – temperature 2 too high |
| B1581F2 | Electric interior heater, 12 V electronics – current too high |
| B168A01 | Electric interior heater – electrical fault |
| B168A16 | Electric interior heater – voltage too low |
| B168A17 | Electric interior heater – voltage too high |
| B168AF0 | Electric interior heater – heating circuit 1 faulty |
| B168AF1 | Electric interior heater – heating circuit 2 faulty |
| B168AF2 | Electric interior heater – heating circuit 3 faulty |
| B16A107 | Evaporator for passenger compartment - iced up |
| B16A111 | Refrigerant circuit shutoff valve (AVK8) – short circuit to ground |
| B16A112 | Refrigerant circuit shutoff valve (AVK8) – short circuit to B+ |
| B16A113 | Refrigerant circuit shut-off valve (AVK8) – open circuit |
| B16A119 | Refrigerant circuit shut-off valve (AVK8) – current too high |
| B16A14B | Refrigerant circuit shut-off valve (AVK8) – temperature too high |
| B16A1F0 | Evaporator for passenger compartment - iced up |
| B16A284 | Refrigerant circuit for passenger compartment cooling – pressure too low |
| B16A285 | Refrigerant circuit for passenger compartment cooling – pressure too high |
| B16A384 | Refrigerant circuit heat pump operation – pressure too low |
| B16A385 | Refrigerant circuit heat pump operation – pressure too high |
| B182C04 | Electric interior heater (Z189), internal error |
| B182C16 | Electric interior heater (Z189), 12V electronics, voltage too low |
| B182C17 | Electric interior heater (Z189), 12V electronics – voltage too high |
| B182C29 | Electric interior heater (Z189), signal implausible |
| B182C31 | Electric interior heater (Z189), no communication |
| B182C4A | Electric interior heater (Z189), part number implausible |
| B182C92 | Electric interior heater (Z189), internal error |
| B182C98 | Electric interior heater (Z189), 12V electronics, temperature too high |
| B182CF0 | Electric interior heater (Z189), coolant input temperature too high |
| B182CF1 | Electric interior heater (Z189), coolant output temperature too high |
| B182CF2 | Electric interior heater (Z189) - 12V electronics, current too high |
| B182CF3 | Electric interior heater (Z189) 800V electronics, electrical error |
| B182CF4 | Electric interior heater (Z189) - 800V electronics, pilot line error |
| B182D01 | Electric interior heater (Z189) 800V electronics, electrical error |
| B182D16 | Electric interior heater (Z189) - 800V electronics, voltage too low |
| B182D17 | Electric interior heater (Z189) - 800V electronics, voltage too high |
| B182DF0 | Electric interior heater (Z189) - 800V electronics, heating circuit 1 faulty |
| B182DF1 | Electric interior heater (Z189) - 800V electronics, heating circuit 2 faulty |
| B182DF2 | Electric interior heater (Z189) - 800V electronics, heating circuit 3 faulty |
| B182DF3 | Electric interior heater (Z189), temperature implausible |
| B182DF4 | Electric interior heater (Z189), coolant input temperature implausible |
| B182DF5 | Electric interior heater (Z189), coolant output temperature implausible |
| B184C00 | Release active |
| B1903F0 | Refrigerant circuit – fill quantity too low |
| B1903F1 | Refrigerant circuit – fill quantity too high |
| B1DA5F2 | Low-temperature circuit for high-voltage battery – cooling performance too low |
| B200041 | Ctrl. module faulty |
| B200500 | Coding |
| B201200 | Coding |
| B303B00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – electrical fault |
| B303D00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – short circuit to B+ |
| B3A0000 | A/C Refrigerant Distribution Valve Actuator "C" Stuck/Open |
| B3A0100 | A/C Refrigerant Distribution Valve Actuator "C" Control, Circuit/Open |
| B3A0200 | A/C Refrigerant Distribution Valve Actuator "C" Control, Circuit Low |
| B3A0300 | A/C Refrigerant Distribution Valve Actuator "C" Control, Circuit High |
| B3A0400 | A/C Refrigerant Distribution Valve "C" Control Circuit Driver, Current/Temperature Too High |
| B3A0500 | Refrigerant circuit shut-off valve (EAV5) – mechanical fault |
| B3A0600 | Refrigerant circuit shut-off valve (EAV5) – fault |
| B3A0700 | Refrigerant circuit shut-off valve (EAV5) – voltage too low |
| B3A0800 | Refrigerant circuit shut-off valve (EAV5) – voltage too high |
| B3A0900 | Refrigerant circuit shut-off valve (EAV5) – temperature too high |
| B3A0A00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – stuck open |
| B3A0C00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – short circuit to ground |
| B3A0E00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – temperature too high |
| B3A1100 | Expansion valve for evaporator, low-temperature circuit (EXV2) – fault |
| B3A1200 | Expansion valve for evaporator, low-temperature circuit (EXV2) – signal implausible |
| B3A1300 | Refrigerant circuit shut-off valve (EAV2) – fault |
| B3A1400 | Refrigerant circuit shut-off valve (EAV2) – temperature implausible |
| B3A1500 | Refrigerant circuit shut-off valve (EAV3) – fault |
| B3A1600 | Refrigerant circuit shut-off valve (EAV3) – temperature implausible |
| B3A1700 | Refrigerant distribution valve 3 – malfunction |
| B3A1800 | A/C Refrigerant Distribution Valve "C" Actuator Temperature, Range/Performance |
| B3A1900 | Refrigerant circuit shut-off valve (EAV5) – fault |
| B3A1A00 | Refrigerant circuit shut-off valve (EAV5) – temperature implausible |
| B3A1B00 | High-voltage battery cooling refrigerant circuit - pressure too high |
| B3A1C00 | Refrigerant circuit – temperature too high |
| B3A3600 | Actuator for aerodynamic function, implausible temperature |
| C200100 | Coding |
| C200200 | Coding |
| P011600 | Coolant temperature sensor at engine outlet – signal implausible |
| P01E300 | Temperature sensor for high-temperature circuit (TW12) – open circuit |
| P01E400 | Temperature sensor for high-temperature circuit (TW12) – signal implausible |
| P01E500 | Temperature sensor for high-temperature circuit (TW12) – short circuit to ground |
| P01E600 | Temperature sensor for high-temperature circuit (TW12) – short circuit to B+ |
| P048000 | Right radiator fan (RF1), PWM signal line – electrical fault |
| P048100 | Left radiator fan (RF3) PWM signal line – electrical fault |
| P053000 | Refrigerant circuit sensor on high pressure side (PT1) – fault |
| P053100 | Refrigerant circuit sensor on high pressure side (PT1) – pressure implausible |
| P053400 | Refrigerant circuit – pressure too low |
| P053500 | A/C Evaporator Temperature Sensor Circuit |
| P053600 | A/C Evaporator Temperature Sensor Circuit, Range/Performance |
| P053700 | A/C Evaporator Temperature Sensor Circuit Low |
| P053800 | A/C Evaporator Temperature Sensor Circuit High |
| P056200 | Supply voltage - voltage too low |
| P056300 | Supply voltage too high |
| P059B00 | Servo motor for cooling-air flaps, right (SM1) – position implausible |
| P059F00 | Servo motor for cooling-air flaps, right (SM1) – blocked |
| P05A000 | Servo motor for cooling-air flaps, right (SM1) – mechanical fault |
| P05A100 | Servo motor for cooling-air flaps, right (SM1) – limit stops implausible |
| P05A300 | Servo motor for cooling-air flaps, right (SM1) – signal implausible |
| P05A600 | Servo motor for cooling-air flaps, right (SM1) – supply voltage implausible |
| P05AA00 | Servo motor for cooling-air flaps, left (SM2) – position implausible |
| P05AE00 | Servo motor for cooling-air flaps, left (SM2) – stuck closed |
| P05AF00 | Servo motor for cooling-air flaps, left (SM2) – mechanical fault |
| P05B000 | Servo motor for cooling-air flaps, left (SM2) – limit stops implausible |
| P05B200 | Servo motor for cooling-air flaps, left (SM2) – signal implausible |
| P05B500 | Servo motor for cooling-air flaps, left (SM2) – supply voltage implausible |
| P05C000 | Servo motor for cooling-air flaps, right (SM1) – temperature too high |
| P05C100 | Servo motor for cooling-air flaps, left (SM2) – temperature too high |
| P060300 | Control unit - function restriction |
| P060400 | Control unit - function restriction |
| P060500 | Control unit - function restriction |
| P060B00 | Control unit – internal error |
| P069100 | Right radiator fan (RF1), PWM signal line – short circuit to ground |
| P069200 | Right radiator fan (RF1), PWM signal line – short circuit to B+ |
| P069300 | Left radiator fan (RF3), PWM signal line – short circuit to ground |
| P069400 | Left radiator fan (RF3), PWM signal line – short circuit to B+ |
| P06B800 | Control unit - function restriction |
| P086400 | Engine electronics (DME) – signal implausible |
| P0C3200 | Low-temperature circuit for high-voltage battery – cooling performance too low |
| P0C4200 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input) – open circuit |
| P0C4300 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input) – signal implausible |
| P0C4400 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input), short circuit to ground |
| P0C4500 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input), short circuit to B+ |
| P0CD500 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output) – open circuit |
| P0CD600 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output) – signal implausible |
| P0CD700 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output), short circuit to ground |
| P0CD800 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output), short circuit to B+ |
| P0CDF00 | Coolant valve 1 for hybrid/high-voltage battery – electrical fault |
| P0CE000 | Coolant valve 1 for hybrid/high-voltage battery – stuck open |
| P0CE100 | Coolant valve 1 for hybrid/high-voltage battery – stuck closed |
| P0CE200 | Coolant valve 1 for hybrid/high-voltage battery – short circuit to ground |
| P0CE300 | Coolant valve 1 for hybrid/high-voltage battery – short circuit to B+ |
| P0CE900 | Coolant pump (P1) – open circuit |
| P0CEB00 | Coolant pump (P1) – short circuit to ground or open circuit |
| P0CEC00 | Coolant pump (P1) – short circuit to B+ |
| P0CEE00 | Temperature sensor for medium-temperature circuit (TW5) – open circuit |
| P0CEF00 | Temperature sensor for medium-temperature circuit (TW5) – signal implausible |
| P0CF000 | Temperature sensor for medium-temperature circuit (TW5) – short circuit to ground |
| P0CF100 | Temperature sensor for medium-temperature circuit (TW5) – short circuit to B+ |
| P0D1A00 | Hybrid/EV Battery Pack Coolant Control Valve "B", Control Circuit/Open |
| P0D1B00 | Hybrid/EV Battery Pack Coolant Control Valve "B", Performance/Stuck Off |
| P0D1C00 | Hybrid/EV Battery Pack Coolant Control Valve "B" Stuck On |
| P0D1D00 | Coolant valve 2 for hybrid/high-voltage battery – short circuit to ground |
| P0D1E00 | Hybrid/EV Battery Pack Coolant Control Valve "B" Control, Circuit High |
| P0D6800 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 1, electrical error |
| P0D6900 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 1, signal implausible |
| P0D6A00 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 1, electrical error |
| P0D6B00 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 1, electrical error |
| P0D6D00 | Electric air-conditioning compressor (V470) - motor, high-voltage supply too low |
| P0D6E00 | Electric air-conditioning compressor (V470) - motor, high-voltage supply too high |
| P0D6F00 | Electric air-conditioning compressor (V470) - motor, high-voltage current consumption too high |
| P0D7000 | Electric air conditioning compressor (V470) - temperature sensor, electrical error |
| P0D7100 | Electric air conditioning compressor (V470) - temperature sensor 1, implausible signal |
| P0D7200 | Electric air conditioning compressor (V470) - temperature sensor, electrical error |
| P0D7300 | Electric air conditioning compressor (V470) - temperature sensor, electrical error |
| P0D7400 | Electric air conditioning compressor (V470) - temperature sensor 1, implausible signal |
| P0D7A00 | Electric air-conditioning compressor (V470) - motor phase U, high-voltage current consumption too low |
| P0D7B00 | Electric air-conditioning compressor (V470) - motor phase U, high-voltage current consumption too high |
| P0D7C00 | Electric air-conditioning compressor (V470) - motor phase V, high-voltage current consumption too low |
| P0D7D00 | Electric air-conditioning compressor (V470) - motor phase V, high-voltage current consumption too high |
| P0D7E00 | Electric air-conditioning compressor (V470) - motor phase W, high-voltage current consumption too low |
| P0D7F00 | Electric air-conditioning compressor (V470), motor phase W, high-voltage current consumption too high |
| P0DE800 | Hybrid/EV Battery Pack Coolant Control Valve "C" Control, Circuit/Open |
| P0DE900 | Hybrid/EV Battery Pack Coolant Control Valve "C", Performance/Stuck Off |
| P0DEA00 | Hybrid/EV Battery Pack Coolant Control Valve "C" Stuck On |
| P0DEB00 | Hybrid/EV Battery Pack Coolant Control Valve "C" Control, Circuit Low |
| P0DEC00 | Hybrid/EV Battery Pack Coolant Control Valve "C" Control, Circuit High |
| P0E2000 | Solenoid valve for low-temperature circuit upstream of chiller (UVW1) – temperature too high |
| P0E2100 | Hybrid/EV Battery Pack Coolant Control Valve "B" Control, Circuit Driver Current/Temperature Too High |
| P0E2200 | Hybrid/EV Battery Pack Coolant Control Valve "C" Control, Circuit Driver Current/Temperature Too High |
| P0E7500 | Coolant bypass valve 1 – open circuit |
| P0E7600 | Coolant bypass valve 1 – short circuit to ground |
| P0E7700 | Coolant bypass valve 1 – short circuit to B+ |
| P0E7800 | Switchover valve for medium-temperature circuit (UVW2, MVW4), temperature implausible |
| P0E7900 | Coolant bypass valve 1 – stuck open |
| P0E7A00 | Coolant bypass valve 1 – stuck closed |
| P0E7B00 | Coolant bypass valve 2 – open circuit |
| P0E7C00 | Coolant bypass valve 2 – short circuit to ground |
| P0E7D00 | Coolant bypass valve 2 – short circuit to B+ |
| P0EA800 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 2, electrical error |
| P0EA900 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 2, signal implausible |
| P0EAA00 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 2, electrical error |
| P0EAB00 | Electric air-conditioning compressor (V470) - motor, high-voltage sensor 2, electrical error |
| P0EAD00 | Electric air-conditioning compressor (V470) - motor, high-voltage current sensor, electrical error |
| P0EAE00 | Electric air-conditioning compressor (V470) - motor high-voltage current sensor, signal implausible |
| P0EAF00 | Electric air-conditioning compressor (V470) - motor, high-voltage current sensor, electrical error |
| P0EB000 | Electric air-conditioning compressor (V470) - motor, high-voltage current sensor, electrical error |
| P0EB100 | Electric air-conditioning compressor (V470) - motor phase U, electrical error |
| P0EB200 | Electric air-conditioning compressor (V470) - motor phase U, electrical error |
| P0EB300 | Electric air-conditioning compressor (V470) - motor phase U, electrical error |
| P0EB400 | Electric air-conditioning compressor (V470), motor phase U, implausible signal |
| P0EB500 | Electric air-conditioning compressor (V470) - motor phase V, electrical error |
| P0EB600 | Electric air-conditioning compressor (V470) - motor phase V, electrical error |
| P0EB700 | Electric air-conditioning compressor (V470), motor phase V, implausible signal |
| P0EB800 | Electric air-conditioning compressor (V470) - motor phase W, electrical error |
| P0EB900 | Electric air-conditioning compressor (V470) - motor phase W, electrical error |
| P0EBA00 | Electric air-conditioning compressor (V470), motor phase W, implausible signal |
| P0EBB00 | Electric air-conditioning compressor (V470) - motor phase V, electrical error |
| P0EBC00 | Refrigerant circuit sensor on high pressure side (PT1) – fault |
| P0EBF00 | Refrigerant circuit sensor on high pressure side (PT1) – temperature implausible |
| P0EC000 | Electric air-conditioning compressor (V470) - motor phase W, electrical error |
| P0EC100 | Refrigerant circuit sensor on low pressure side (PT2) – fault |
| P0EC400 | Refrigerant circuit sensor on low pressure side (PT2) – temperature implausible |
| P0EC500 | Electric air-conditioning compressor (V470) - motor speed sensor, signal implausible |
| P0EC900 | Refrigerant circuit shut-off valve (EAV2) – mechanical fault |
| P0EE200 | Refrigerant circuit shut-off valve (EAV3) – mechanical fault |
| P0EE300 | Refrigerant circuit shut-off valve (EAV3) – fault |
| P0EE400 | Refrigerant circuit shut-off valve (EAV3) – voltage too low |
| P0EE500 | Refrigerant circuit shut-off valve (EAV3) – voltage too high |
| P0EE600 | Refrigerant circuit shut-off valve (EAV3) – temperature too high |
| P10C100 | Electric A/C compressor, control unit – supply voltage too high |
| P10C200 | Electric A/C compressor, control unit – supply voltage too low |
| P10C300 | Electric air-conditioning compressor (V470) - control unit, temperature too high |
| P10C400 | Electric air-conditioning compressor (V470) - control unit, temperature too low |
| P10C500 | Electric A/C compressor, motor – overload protection active |
| P10C700 | Electric A/C compressor, motor – starting current too high |
| P10CD00 | Solenoid valve for low-temperature circuit upstream of chiller (UVW1) – current too high |
| P10CE00 | Valve 2 for coolant of hybrid/high-voltage battery, Excess current |
| P10CF00 | Valve 3 for coolant of hybrid/high-voltage battery, Excess current |
| P10D000 | Coolant change-over valve 2, Excess current |
| P10D100 | Coolant change-over valve 3, Excess current |
| P10D200 | Electric air-conditioning compressor (V470), part number implausible |
| P10D300 | Expansion valve for evaporator, passenger compartment (EXV3) – part number implausible |
| P10D500 | Expansion valve for evaporator, passenger compartment (EXV3) – part number implausible |
| P10D600 | Refrigerant cut-off valve 1, Incorrect component installed |
| P10DB00 | Refrigerant circuit sensor on high pressure side (PT1) – part number implausible |
| P10DC00 | Refrigerant circuit sensor on low pressure side (PT2) – part number implausible |
| P10DD00 | Refrigerant circuit sensor on low pressure side (PT3) – part number implausible |
| P10DE00 | A/C pressure/temperature sensor 4, Incorrect component installed |
| P10DF00 | A/C pressure/temperature sensor 5, Incorrect component installed |
| P10E400 | Coolant fan control module, No signal |
| P10E500 | Coolant fan control module 2, No signal |
| P10E600 | Drain and fill refrigerant circuit function – active |
| P10E700 | Clean refrigerant circuit function – active |
| P10E800 | Bleed cooling systems function – active |
| P139B00 | Coolant level sensor (LS2) – coolant level too low |
| P139C00 | Coolant level sensor (LS2) – coolant level too low |
| P13F000 | Passenger compartment preconditioning – running time restriction |
| P13F100 | Passenger compartment preconditioning – could not be started |
| P175700 | Power supply (terminal 30) – open circuit |
| P191B00 | Right radiator fan (RF1) – signal implausible |
| P191C00 | Left radiator fan (RF3) – signal implausible |
| P194400 | Right radiator fan (RF1) – temperature too high |
| P194700 | Left radiator fan (RF3) – temperature too high |
| P19FB00 | Directional-control valve for high-temperature circuit (MVW1) – mechanical fault |
| P19FC00 | Directional-control valve for high-temperature circuit (MVW1) – fault |
| P19FD00 | Directional-control valve for high-temperature circuit (MVW1) – voltage too high |
| P19FE00 | Directional-control valve for high-temperature circuit (MVW1) – voltage too low |
| P19FF00 | Directional-control valve for high-temperature circuit (MVW1) – temperature too high |
| P1A3900 | Directional-control valve for high-temperature circuit (MVW1) – signal implausible |
| P1A3A00 | Directional-control valve for high-temperature circuit (MVW1) – not taught |
| P1A3B00 | Directional-control valve for high-temperature circuit (MVW1) – no communication |
| P1A3C00 | Directional-control valve for high-temperature circuit (MVW1) – part number implausible |
| P1A3D00 | Directional-control valve for medium-temperature circuit (MVW2) – fault |
| P1A3E00 | Directional-control valve for medium-temperature circuit (MVW2) – mechanical fault |
| P1A3F00 | Directional-control valve for medium-temperature circuit (MVW2) – temperature too high |
| P1A4000 | Directional-control valve for medium-temperature circuit (MVW2) – voltage too high |
| P1A4100 | Directional-control valve for medium-temperature circuit (MVW2) – voltage too low |
| P1A4200 | Directional-control valve for medium-temperature circuit (MVW2) – signal implausible |
| P1A4300 | Directional-control valve for medium-temperature circuit (MVW2) – no communication |
| P1A4400 | Directional-control valve for medium-temperature circuit (MVW2) – not taught |
| P1A4500 | Directional-control valve for medium-temperature circuit (MVW2) – part number implausible |
| P1A4600 | Change-over valve for low-temperature circuit (UVW4, MVW3), error |
| P1A4700 | Change-over valve for low-temperature circuit (UVW4, MVW3), mechanical error |
| P1A4800 | Change-over valve for low-temperature circuit (UVW4, MVW3), temperature too high |
| P1A4900 | Change-over valve for low-temperature circuit (UVW4, MVW3), voltage too high |
| P1A4A00 | Change-over valve for low-temperature circuit (UVW4, MVW3), voltage too low |
| P1A4B00 | Change-over valve for low-temperature circuit (UVW4, MVW3), signal implausible |
| P1A4C00 | Change-over valve for low-temperature circuit (UVW4, MVW3), no communication |
| P1A4D00 | Change-over valve for low-temperature circuit (UVW4, MVW3), not taught |
| P1A4E00 | Change-over valve for low-temperature circuit (UVW4, MVW3), part number implausible |
| P1A4F00 | Change-over valve for low-temperature circuit (UVW7) – internal fault |
| P1A5000 | Change-over valve for low-temperature circuit (UVW7) – mechanical fault |
| P1A5100 | Change-over valve for low-temperature circuit (UVW7) – temperature too high |
| P1A5200 | Change-over valve for low-temperature circuit (UVW7) – voltage too high |
| P1A5300 | Change-over valve for low-temperature circuit (UVW7) – voltage too low |
| P1A5400 | Switchover valve for low-temperature circuit upstream of heat exchanger (UVW7) – signal implausible |
| P1A5500 | Change-over valve for low-temperature circuit (UVW7) – no communication |
| P1A5600 | Change-over valve for low-temperature circuit (UVW7) – not taught |
| P1A5700 | Change-over valve for low-temperature circuit (UVW7) – part number implausible |
| P1A7500 | Right radiator fan (RF1), enable line – open circuit |
| P1A7600 | Right radiator fan (RF1), enable line – short circuit to ground |
| P1A7700 | Right radiator fan (RF1), enable line – short circuit to B+ |
| P1A7800 | Left radiator fan (RF3), enable line – open circuit |
| P1A7900 | Left radiator fan (RF3), enable line – short circuit to ground |
| P1A7A00 | Left radiator fan (RF3), enable line – short circuit to B+ |
| P1A7B00 | Right radiator fan (RF1) – part number implausible |
| P1A7C00 | Left radiator fan (RF3) – part number implausible |
| P1A8100 | Cooling system drain and fill/check function – active |
| P1A8200 | Refrigerant circuit sensor on high-pressure side - pressure too high |
| P1A8300 | Camshaft adjustment, Replacement reaction active |
| P1A8700 | Refrigerant circuit shut-off valve (EAV2) – part number implausible |
| P1A8900 | Refrigerant circuit shut-off valve (EAV3) – part number implausible |
| P1A8A00 | Valve 3 for refrigerant, Incorrect component installed |
| P1A8B00 | Refrigerant circuit shut-off valve (EAV5) – part number implausible |
| P1A8C00 | Refrigerant circuit shut-off valve (EAV2) – not taught |
| P1A8D00 | Refrigerant circuit shut-off valve (EAV3) – not taught |
| P1A8E00 | Valve 3 for refrigerant, wrong address |
| P1A8F00 | Refrigerant circuit shut-off valve (EAV5) – not taught |
| P1A9000 | Sensors for refrigerant circuit (PT1/PT2/PT3) – pressure signal deviation too large |
| P1B5B00 | Directional-control valve for high-temperature circuit (WMV1) – temperature implausible |
| P1B5C00 | Directional-control valve for high-temperature circuit (WMV1) – mechanical fault |
| P1B5D00 | Directional-control valve for high-temperature circuit (WMV1) – signal implausible |
| P1B5E00 | Directional-control valve for high-temperature circuit (WMV1) – voltage too low |
| P1B5F00 | Directional-control valve for high-temperature circuit (WMV1) – voltage too high |
| P1B6000 | Directional-control valve for high-temperature circuit (WMV1) – faulty |
| P1B6100 | Directional-control valve for high-temperature circuit (WMV1) – temperature too high |
| P1B6200 | Directional-control valve for high-temperature circuit (WMV1) – timeout during reference operation |
| P1B6300 | Directional-control valve for high-temperature circuit (WMV1) – not taught |
| P1B6400 | Directional-control valve for high-temperature circuit (WMV1) – part number implausible |
| P1B6500 | Expansion valve for evaporator, passenger compartment (EXV3) – temperature implausible |
| P1B8200 | Change-over valve for medium-temperature circuit (UVW1) – fault |
| P1B8300 | Change-over valve for medium-temperature circuit (UVW1) – mechanical fault |
| P1B8400 | Change-over valve for medium temperature circuit (UVW1) – temperature too high |
| P1B8500 | Change-over valve for medium-temperature circuit (UVW1) – voltage too low |
| P1B8600 | Change-over valve for medium-temperature circuit (UVW1) – signal implausible |
| P1B8700 | Change-over valve for medium-temperature circuit (UVW1) – no communication |
| P1B8800 | Change-over valve for medium-temperature circuit (UVW1) – not taught |
| P1B8900 | Change-over valve for medium-temperature circuit (UVW1) – part number implausible |
| P1B8A00 | Change-over valve for medium-temperature circuit (UVW1) – voltage too high |
| P1B8B00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – not taught |
| P1B8C00 | Change-over valve for medium-temperature circuit (UVW2, MVW4), error |
| P1B8D00 | Change-over valve for medium-temperature circuit (UVW2, MVW4), mechanical error |
| P1B8E00 | Change-over valve for medium temperature circuit (UVW2, MVW4), temperature too high |
| P1B8F00 | Change-over valve for medium-temperature circuit (UVW2, MVW4), voltage too high |
| P1B9000 | Change-over valve for medium-temperature circuit (UVW2, MVW4), voltage too low |
| P1B9100 | Change-over valve for medium-temperature circuit (UVW2, MVW4), signal implausible |
| P1B9200 | Change-over valve for medium-temperature circuit (UVW2, MVW4), no communication |
| P1B9300 | Change-over valve for medium-temperature circuit (UVW2, MVW4), not taught |
| P1B9400 | Change-over valve for medium-temperature circuit (UVW2, MVW4), part number implausible |
| P1B9500 | Coolant valve 7, faulty |
| P1B9600 | Coolant valve 7, mechanical malfunction |
| P1B9700 | Coolant valve 7, Excessive temperature |
| P1B9800 | Coolant valve 7, Excessive voltage |
| P1B9900 | Coolant valve 7, Insufficient voltage |
| P1B9A00 | Coolant valve 7, Implausible signal |
| P1B9B00 | Coolant valve 7, No signal |
| P1B9C00 | Coolant valve 7, wrong address |
| P1B9D00 | Coolant valve 7, Incorrect component installed |
| P1BA500 | Right radiator fan (RF1) – voltage too high |
| P1BA600 | Right radiator fan (RF1) – voltage too low |
| P1BA700 | Right radiator fan (RF1) – faulty |
| P1BA800 | Right radiator fan (RF1) – speed implausible |
| P1BA900 | Right radiator fan (RF1) – voltage implausible |
| P1BAA00 | Right radiator fan (RF1) – temperature implausible |
| P1BAB00 | Right radiator fan (RF1) – current implausible |
| P1BAC00 | Left radiator fan (RF3) – voltage too low |
| P1BAD00 | Left radiator fan (RF3) – voltage too high |
| P1BAE00 | Left radiator fan (RF3) – faulty |
| P1BAF00 | Left radiator fan (RF3) – speed implausible |
| P1BB000 | Left radiator fan (RF3) – voltage implausible |
| P1BB100 | Left radiator fan (RF3) – temperature implausible |
| P1BB200 | Left radiator fan (RF3) – current implausible |
| P1BB600 | Radiator fan relay – short circuit to ground |
| P1BB700 | Radiator fan relay – short circuit to B+ |
| P1BB800 | Radiator fan relay – open circuit |
| P1BB900 | Radiator fan relay – permanently active |
| P1BED00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – part number implausible |
| P1C0100 | Expansion valve for evaporator, passenger compartment (EXV3) - fault |
| P1C0200 | Expansion valve for evaporator, passenger compartment (EXV3) – mechanical fault |
| P1C0300 | Expansion valve for evaporator, passenger compartment (EXV3) – temperature too high |
| P1C0400 | Expansion valve for evaporator, passenger compartment (EXV3) – voltage too high |
| P1C0500 | Expansion valve for evaporator, passenger compartment (EXV3) – voltage too low |
| P1C0600 | Expansion valve for evaporator, passenger compartment (EXV3) – signal implausible |
| P1C0700 | Expansion valve for evaporator, passenger compartment (EXV3) – no communication |
| P1C0800 | Expansion valve for evaporator, passenger compartment (EXV3) – not taught |
| P1C0A00 | Expansion valve 2 for coolant, mechanical malfunction |
| P1C0E00 | Expansion valve 2 for coolant, Implausible signal |
| P1C0F00 | Expansion valve 2 for coolant, No signal |
| P1C1100 | Expansion valve for evaporator, passenger compartment (EXV3) - fault |
| P1C1200 | Expansion valve for evaporator, passenger compartment (EXV3) – mechanical fault |
| P1C1300 | Expansion valve for evaporator, passenger compartment (EXV3) – temperature too high |
| P1C1400 | Expansion valve for evaporator, passenger compartment (EXV3) – voltage too high |
| P1C1500 | Expansion valve for evaporator, passenger compartment (EXV3) – voltage too low |
| P1C1600 | Expansion valve for evaporator, passenger compartment (EXV3) – signal implausible |
| P1C1700 | Expansion valve for evaporator, passenger compartment (EXV3) – no communication |
| P1C1800 | Expansion valve for evaporator, passenger compartment (EXV3) – not taught |
| P1C1900 | Refrigerant cut-off valve 1, Faulty |
| P1C1A00 | Refrigerant shut-off valve 1 – mechanical fault |
| P1C1B00 | Shutoff valve 1 for refrigerant – overtemperature |
| P1C1C00 | Refrigerant cut-off valve 1, Excess voltage |
| P1C1D00 | Shutoff valve 1 for refrigerant – undervoltage |
| P1C1E00 | Shutoff valve 1 for refrigerant – implausible signal |
| P1C1F00 | Refrigerant cut-off valve 1, No signal |
| P1C2000 | Refrigerant cut-off valve 1, wrong address |
| P1C2600 | Refrigerant cut-off valve 2, Implausible signal |
| P1C2E00 | Refrigerant cut-off valve 3, Implausible signal |
| P1C3200 | Refrigerant cut-off valve 4, mechanical malfunction |
| P1C3600 | Refrigerant cut-off valve 4, Implausible signal |
| P1C3A00 | Refrigerant cut-off valve 5, mechanical malfunction |
| P1C3F00 | Refrigerant cut-off valve 5, No signal |
| P1C4100 | Relay for thermal management components (SR6.2) – open circuit |
| P1C4200 | Relay for thermal management components (SR6.2) – short circuit to ground |
| P1C4300 | Relay for thermal management components (SR6.2) – short circuit to B+ |
| P1C4400 | Solenoid valve for low-temperature circuit upstream of chiller (UVW1) – open circuit |
| P1C4500 | Coolant valve 1 for hybrid/high-voltage battery – short circuit to ground |
| P1C4600 | Coolant valve 1 for hybrid/high-voltage battery – short circuit to B+ |
| P1C4C00 | Coolant change-over valve 2, Excess temp. |
| P1C5100 | Coolant change-over valve 3, Excess temp. |
| P1C5800 | A/C pressure/temperature sensor 1, Implausible signal |
| P1C5900 | Refrigerant circuit sensor on high pressure side (PT1) – faulty |
| P1C5B00 | A/C pressure/temperature sensor 2, Implausible signal |
| P1C5C00 | Refrigerant circuit sensor on low pressure side (PT2) – faulty |
| P1C5E00 | Refrigerant circuit sensor on low pressure side (PT3) - signal implausible |
| P1C5F00 | Refrigerant circuit sensor on low pressure side (PT3) – fault |
| P1C6000 | Refrigerant circuit sensor on low pressure side (PT3) – no communication |
| P1C6100 | A/C pressure/temperature sensor 4, Implausible signal |
| P1C6200 | A/C pressure/temperature sensor 4, Faulty |
| P1C6300 | A/C pressure/temperature sensor 4, No signal |
| P1C6400 | A/C pressure/temperature sensor 5, Implausible signal |
| P1C6500 | A/C pressure/temperature sensor 5, Faulty |
| P1C6600 | A/C pressure/temperature sensor 5, No signal |
| P1C6A00 | Voltage supply for sensors, Open circuit |
| P1C6B00 | Voltage supply for sensors, Short circuit to ground |
| P1C6C00 | Voltage supply for sensors, Short circuit to B+ |
| P1CA300 | Medium-temperature circuit for drive, front – cooling performance too low |
| P1CA400 | Change-over valve for medium-temperature circuit (UVW1) – mechanical fault |
| P1CA500 | Change-over valve for medium-temperature circuit (UVW2, MVW4), mechanical error |
| P1CA600 | Change-over valve for medium-temperature circuit (UVW1) – part number implausible |
| P1CDF00 | Refrigerant circuit sensor on low pressure side (PT3) – temperature signal deviation too high |
| P1CE000 | Expansion valve for evaporator, passenger compartment (EXV3) – mechanical fault |
| P1CE500 | Servo motor for cooling-air flaps, right (SM1) – temperature implausible |
| P1CE600 | Servo motor for cooling-air flaps, left (SM2) – temperature implausible |
| P1CE800 | High-voltage battery coolant outlet temperature sensor, temperature implausible |
| P1CE900 | High-voltage battery coolant inlet temperature sensor, temperature implausible |
| P1E8A00 | Electric interior heater (Z189), coolant input temperature implausible |
| P1E9100 | Electric interior heater (Z189), coolant output temperature implausible |
| P218200 | Temperature sensor for high-temperature circuit (TW11) – open circuit |
| P218300 | Temperature sensor for high-temperature circuit (TW11) – signal implausible |
| P218400 | Temperature sensor for high-temperature circuit (TW11) – short circuit to ground |
| P218500 | Temperature sensor for high-temperature circuit (TW11) – short circuit to B+ |
| P251500 | Refrigerant circuit sensor on low pressure side (PT2) – fault |
| P251600 | Refrigerant circuit sensor on low pressure side (PT2) – pressure implausible |
| P260000 | Coolant pump – open circuit |
| P260200 | Coolant pump – short circuit to ground |
| P260300 | Coolant pump – short circuit to B+ |
| P261100 | Refrigerant circuit shut-off valve (EAV2) – fault |
| P261200 | Refrigerant circuit shut-off valve (EAV2) – voltage too low |
| P261300 | Refrigerant circuit shut-off valve (EAV2) – voltage too high |
| P261A00 | Additional coolant pump (P5) – open circuit |
| P261C00 | Additional coolant pump (P5) – short circuit to ground or open circuit |
| P261D00 | Additional coolant pump (P5) – short circuit to B+ |
| P261E00 | Additional coolant pump (P5) – blocked |
| P261F00 | Coolant pump – blocked |
| P266F00 | Refrigerant circuit shut-off valve (EAV2) – temperature too high |
| P268100 | Coolant bypass valve – open circuit |
| P268200 | Coolant bypass valve – short circuit to ground |
| P268300 | Coolant bypass valve – short circuit to B+ |
| P26AB00 | Coolant bypass valve – stuck open |
| P26B100 | Coolant bypass valve – blocked in closed position |
| P26F400 | Coolant pump (P8, P3), open circuit |
| P26F500 | Coolant pump (P8, P3), short circuit to ground or open circuit |
| P26F600 | Coolant pump (P8, P3), short circuit to B+ |
| P26F800 | Coolant pump (P8) – blocked |
| P26F900 | Coolant pump (P8, P3), temperature too high |
| P26FA00 | Coolant pump (P8, P3), dry run |
| P26FD00 | Electric air-conditioning compressor (V470) - control unit, error |
| P293600 | Temperature sensor for medium-temperature circuit (TW9) – open circuit |
| P293700 | Temperature sensor for medium-temperature circuit (TW9) – signal implausible |
| P293800 | Temperature sensor for medium-temperature circuit (TW9) – short circuit to ground |
| P293900 | Temperature sensor for medium-temperature circuit (TW9) – short circuit to B+ |
| P2AFC00 | Temperature sensor for medium-temperature circuit (TW9) – open circuit |
| P2AFD00 | Temperature sensor for medium-temperature circuit (TW9) – signal implausible |
| P2AFE00 | Temperature sensor for medium-temperature circuit (TW9) – short circuit to ground |
| P2AFF00 | Temperature sensor for medium-temperature circuit (TW9) – short circuit to B+ |
| P2B2000 | Temperature sensor for high-temperature circuit (G1018 - TW14), open circuit |
| P2B2100 | Temperature sensor for high-temperature circuit (G1018 - TW14), signal implausible |
| P2B2200 | Temperature sensor for high-temperature circuit (G1018 - TW14), short circuit to ground |
| P2B2300 | Temperature sensor for high-temperature circuit (G1018 - TW14), short circuit to B+ |
| P2B2400 | Temperature sensor for medium-temperature circuit (TW10) – open circuit |
| P2B2500 | Temperature sensor for medium-temperature circuit (TW10) – signal implausible |
| P2B2600 | Temperature sensor for medium-temperature circuit (TW10) – short circuit to ground |
| P2B2700 | Temperature sensor for medium-temperature circuit (TW10) – short circuit to B+ |
| P2B2A00 | Coolant pump (P1) – dry run |
| P2B2B00 | Temperature sensor for medium-temperature circuit (TW4) – open circuit |
| P2B2C00 | Temperature sensor for medium-temperature circuit (TW4) – signal implausible |
| P2B2D00 | Temperature sensor for medium-temperature circuit (TW4) – short circuit to ground |
| P2B2E00 | Temperature sensor for medium-temperature circuit (TW4) – short circuit to B+ |
| P2B2F00 | Right radiator fan (RF1) – performance too low |
| P2B3000 | Right radiator fan (RF1) – blocked |
| P2B3100 | Left radiator fan (RF3) – performance too low |
| P2B3200 | Left radiator fan (RF3) – blocked |
| P2B6400 | Additional coolant pump (P5) – temperature too high |
| P2B6500 | Additional coolant pump (P5) – dry run |
| P2B8600 | Coolant pump – dry run |
| P2B9E00 | Coolant pump – temperature too high |
| P2C6600 | Coolant pump (P1) – sluggish |
| P2C6800 | Coolant pump (P1) – blocked |
| P2C7200 | Medium-temperature circuit for drive, rear – cooling power too low |
| P2CD400 | Sensors for refrigerant circuit (PT1/PT2/PT3) – pressure signal deviation too large |
| P2D2900 | Electric air-conditioning compressor (V470) - motor, mechanical block |
| P2D2A00 | Medium-temperature circuit – temperature implausible (TW5/TW9/TW10) |
| P2D2B00 | Low-temperature circuit – temperature implausible (TW7/TW8) |
| P2D2C00 | High-temperature circuit – temperature implausible (TW11/TW12) |
| P2D3800 | Low-temperature circuit for high-voltage battery – heating performance too low |
| P2D4200 | Electric air-conditioning compressor (V470) - control unit, 12V supply voltage too low |
| P2D4300 | Electric air-conditioning compressor (V470) - control unit, – 12V supply voltage too high |
| P2D4400 | Electric air-conditioning compressor (V470) – overload protection active |
| P2E7C00 | Electric air-conditioning compressor (V470) - temperature sensor 2, interruption |
| P2E7D00 | Electric air-conditioning compressor (V470) - temperature sensor 2, implausible signal |
| P2E7E00 | Electric air-conditioning compressor (V470), temperature sensor 2, short-circuit to plus |
| P2E7F00 | Electric air-conditioning compressor (V470), temperature sensor 2, short-circuit to ground |
| P2E8000 | Electric air-conditioning compressor (V470) - temperature sensor 2, implausible signal |
| U002800 | Hybrid CAN bus – faulty |
| U002900 | Hybrid CAN bus - no communication |
| U009200 | LIN bus 1 – electrical fault |
| U009300 | LIN bus 1 – no communication |
| U010000 | Engine electronics (DME) control unit – no communication |
| U010100 | Lost Communication with TCM |
| U011000 | High-voltage power electronics control unit - no communication |
| U011200 | High-voltage battery control unit – no communication |
| U011900 | Fuel cell control unit, no communication |
| U012100 | Brake electronics (PSM) control unit – no communication |
| U012A00 | Control unit for chassis control (PASM) – no communication |
| U014000 | Front-end electronics control unit (BCM1) - missing message |
| U014100 | Front-end electronics control unit (BCM1) - no communication |
| U014600 | Gateway control unit - no communication |
| U015100 | Airbag control unit - missing message |
| U015500 | Instrument cluster control unit - missing message |
| U016300 | Central computer (PCM) control unit - missing message |
| U016400 | Air conditioner control unit - missing message |
| U016B00 | Electric air-conditioning compressor (V470), no communication |
| U019900 | Driver-side door control unit - no communication |
| U019B00 | High-voltage charger (OBC) control unit – missing message |
| U020000 | Door control unit, passengerʼs side - no communication |
| U020100 | Control unit for door on rear driver’s side - no communication |
| U020200 | Control unit for door on rear passenger’s side - no communication |
| U028400 | Servo motor for cooling-air flaps, right (SM1) – no communication |
| U028500 | Servo motor for cooling-air flaps, left (SM2) – no communication |
| U029200 | Front-axle high-voltage power electronics control unit - no communication |
| U029800 | Control unit for high-voltage voltage converter (combi converter) - missing message |
| U029900 | Control unit for high-voltage voltage converter (booster) - missing message |
| U029B00 | High-voltage power electronics 3 control unit - missing message |
| U02AD00 | Boost pressure actuator for turbocharger 2, no communication |
| U032A00 | Electric air-conditioning compressor (V470), part number implausible |
| U034E00 | Servo motor for cooling-air flaps, right (SM1) – software implausible |
| U034F00 | Servo motor for cooling-air flaps, left (SM2) – software implausible |
| U040100 | Engine electronics (DME) control unit – signal implausible |
| U040E00 | Boost pressure actuator for turbocharger 2, no communication |
| U041100 | High-voltage power electronics control unit – signal implausible |
| U041300 | High-voltage battery control unit, signal implausible |
| U041500 | Control unit for brake electronics (PSM) – signal implausible |
| U042200 | Front-end electronics control unit (BCM1) - signal implausible |
| U042300 | Instrument cluster control unit – signal implausible |
| U042400 | Air conditioning control unit - signal implausible |
| U042500 | Auxiliary heater control unit – signal implausible |
| U042B00 | Control unit for chassis control (PASM) – signal implausible |
| U044700 | Gateway control unit – signal implausible |
| U046400 | Central computer (PCM) control unit – signal implausible |
| U046800 | Fuel cell control unit, implausible signal |
| U046C00 | Electric air-conditioning compressor (V470), – signal implausible |
| U049C00 | High-voltage charger control unit (OBC) - signal implausible |
| U058500 | Servo motor for cooling-air flaps, right (SM1) – signal implausible |
| U058600 | Servo motor for cooling-air flaps, left (SM2) – signal implausible |
| U059300 | High-voltage power electronics control unit, front axle - signal implausible |
| U059900 | Control unit for high-voltage voltage converter (combi converter) - signal implausible |
| U059A00 | Control unit for high-voltage voltage converter (booster) - signal implausible |
| U059C00 | High-voltage power electronics 3 control unit – signal implausible |
| U062300 | Coolant pump – no communication |
| U062400 | Additional coolant pump (P5) – no communication |
| U062600 | Refrigerant circuit sensor on high pressure side (PT1) – no communication |
| U062800 | Refrigerant circuit sensor on low pressure side (PT2) – no communication |
| U062A00 | Refrigerant circuit shut-off valve (EAV2) – no communication |
| U062B00 | Refrigerant circuit shut-off valve (EAV3) – no communication |
| U062C00 | Lost Communication With A/C Refrigerant Distribution Valve, Actuator “C” |
| U062D00 | Refrigerant circuit shut-off valve (EAV5) – no communication |
| U062E00 | Expansion valve for evaporator, low-temperature circuit (EXV2) – no communication |
| U062F00 | Coolant pump (P8, P3), no communication |
| U063200 | Right radiator fan (RF1) – no communication |
| U063300 | Left radiator fan (RF3) – no communication |
| U063D00 | Additional coolant pump (P1) – no communication |
| U103000 | LIN bus 1 – electrical fault |
| U103C00 | Electric air-conditioning compressor (V470), – signal implausible |
| U105400 | Central computer control unit - missing message |
| U105500 | Central computer control unit – signal implausible |
| U107600 | LIN bus 2 - electrical fault |
| U10BA00 | LIN bus 1 – no communication |
| U10C700 | LIN bus 2 – no communication |
| U10C800 | LIN bus 3 - no communication |
| U10DB00 | LIN bus 3 - electrical fault |
| U110300 | Production mode active |
| U110400 | Expanded bus operation active |
| U110500 | Transport mode active |
| U112100 | Data bus - missing message |
| U112300 | Data bus – fault value received |
| U11DC00 | Charging module, contactless high-voltage charging (AWC) - missing message |
| U12B900 | Control unit for driver assistance systems – missing message |
| U140000 | Function restriction – supply voltage too low |
| U140100 | Function restriction – supply voltage too high |
| U140B00 | Energy management active |
| U148100 | Charging module for contactless high-voltage charging (AWC) - implausible signal |
| U14C100 | Directional-control valve for high-temperature circuit (WMV1) – no communication |
| U300000 | Relay for thermal management components (SR6.2) – short circuit to ground |
| U300100 | Control unit – run-on fault |
| U366700 | LIN bus 2 - electrical fault |