All 209 fault codes
| Code | Fault |
|---|---|
| B11B300 | Ignition circuit for high-voltage battery disconnection element - equipment fault |
| B184C00 | Release active |
| B1A7BF0 | Control unit faulty |
| B1D9EF0 | Cell module 1, aging detected |
| B1D9EF1 | Cell module 2, aging detected |
| B1D9EF2 | Cell module 3, aging detected |
| B1D9EF3 | Cell module 4, aging detected |
| B1D9EF4 | Cell module 5, aging detected |
| B1D9EF5 | Cell module 6, aging detected |
| B1D9EF6 | Cell module 7, aging detected |
| B1D9EF7 | Cell module 8, aging detected |
| B1D9EF8 | Cell module 9, aging detected |
| B1D9EF9 | Cell module 10, aging detected |
| B1D9EFA | Cell module 11, aging detected |
| B1D9EFB | Cell module 12, aging detected |
| B200500 | Coding |
| B201200 | Coding |
| B2F0100 | Development code 1 |
| B2F0200 | Development code 2 |
| B2F0300 | Development code 3 |
| B2F0400 | Development code 4 |
| B2F0500 | Development code 5 |
| B2F0600 | Development code 6 |
| B2F0700 | Development code 7 |
| B2F0800 | Development code 8 |
| B2F0900 | Development code 9 |
| B2F0A00 | Development code 10 |
| B2F0B00 | Development code 11 |
| B2F0C00 | Development code 12 |
| B2F0D00 | Development code 13 |
| B2F0E00 | Development code 14 |
| C11BAF0 | High-voltage battery control unit - procedural error while setting operating mode |
| P056000 | Terminal 30 power supply – signal implausible |
| P056200 | Supply voltage - voltage too low |
| P056300 | Supply voltage too high |
| P060100 | Function restriction |
| P060200 | Programming |
| P060400 | Control unit - function restriction |
| P060500 | Control unit - function restriction |
| P060600 | Control unit defective |
| P061000 | Control unit - variant coding invalid |
| P062F00 | Function restriction |
| P064F00 | Coding |
| P06B800 | Control unit - function restriction |
| P0A0A00 | High Voltage System Inter-Lock Circuit |
| P0A0C00 | High Voltage System Interlock Circuit Low |
| P0A0D00 | High Voltage System Interlock Circuit High |
| P0A0E00 | High-voltage system, pilot line – open circuit |
| P0A1F00 | Terminal 30 power supply – signal implausible |
| P0A7E00 | Backup battery, temperature critical |
| P0A7F00 | Hybrid/EV Battery Pack Deterioration |
| P0A9400 | Function limitation |
| P0A9500 | High Voltage Fuse |
| P0A9C00 | Hybrid Battery Temperature Sensor "A" Circuit Range/Performance |
| P0A9D00 | Temperature sensor 1 for hybrid/high-voltage battery - short circuit to ground |
| P0A9E00 | Temperature sensor 1 for hybrid/high-voltage battery - short circuit to B+ |
| P0AA100 | Hybrid/EV Battery Positive Contactor Circuit, Stuck Closed |
| P0AA200 | Hybrid/EV Battery Positive Contactor Circuit, Stuck Open |
| P0AA400 | Hybrid/EV Battery Negative Contactor Circuit Stuck Closed |
| P0AA500 | Hybrid/EV Battery Negative Contactor Circuit Stuck Open |
| P0AA600 | Hybrid/EV Battery Voltage System Isolation Fault |
| P0ABA00 | Hybrid/high-voltage battery total voltage 1 – limit value violated |
| P0ABB00 | Hybrid/EV Battery Pack Voltage Sense "A" Circuit, Range/Performance |
| P0AC000 | Hybrid/EV Battery Pack Current Sensor "A" Circuit, Range/Performance |
| P0AC100 | Hybrid/EV Battery Pack Current Sensor "A", Circuit Low |
| P0AC200 | Hybrid/EV Battery Pack Current Sensor "A", Circuit High |
| P0AD900 | Hybrid/EV Battery Positive Contactor Control Circuit/Open |
| P0ADB00 | Activation of hybrid/high-voltage battery positive contact – short circuit to ground |
| P0ADC00 | Activation of hybrid/high-voltage battery positive contact, short circuit to B+ |
| P0ADD00 | Hybrid/EV Battery Negative Contactor Control Circuit/Open |
| P0ADF00 | Activation of hybrid/high-voltage battery negative contact, short circuit to ground |
| P0AE000 | Activation of hybrid/high-voltage battery negative contact, short circuit to B+ |
| P0AE200 | Pre-charging contacts of hybrid/high-voltage battery – stuck closed |
| P0AE300 | Hybrid/EV Battery Precharge Contactor Circuit, Stuck Open |
| P0AE400 | Hybrid/EV Battery Precharge Contactor Control Circuit |
| P0AE600 | Hybrid/EV Battery Precharge Contactor Control Circuit Low |
| P0AE700 | Hybrid/EV Battery Precharge Contactor Control Circuit High |
| P0AF800 | Backup battery, voltage fault |
| P0AFA00 | High-voltage system - voltage too low |
| P0AFB00 | High-voltage system - voltage too high |
| P0B0F00 | Hybrid/EV Battery Pack Current Sensor "B" Circuit, Range/Performance |
| P0B1000 | Current measurement sensor 2 for hybrid/high-voltage battery - short circuit to ground |
| P0B1100 | Hybrid/EV Battery Pack Current Sensor "B" Circuit High |
| P0B1300 | Hybrid/EV Battery Pack Current Sensor "A"/"B" Correlation |
| P0B1500 | Hybrid/EV Battery Pack Voltage Sense "B" Circuit, Range/Performance |
| P0B1600 | Hybrid/EV Battery Pack Voltage Sense "B" Circuit Low |
| P0B1700 | Hybrid/EV Battery Pack Voltage Sense "B" Circuit High |
| P0B1A00 | Hybrid/EV Battery Pack Voltage Sense "C" Circuit, Range/Performance |
| P0B1B00 | Hybrid/EV Battery Pack Voltage Sense "C" Circuit Low |
| P0B1C00 | Hybrid/EV Battery Pack Voltage Sense "C" Circuit High |
| P0B3300 | High-voltage battery voltage supply – below limit value |
| P0B3400 | High Voltage Service Disconnect Circuit, Performance |
| P0B3500 | High Voltage Service Disconnect Circuit Low |
| P0B3600 | High Voltage Service Disconnect Circuit High |
| P0B3700 | High Voltage Service Disconnect Open |
| P0B3C00 | Hybrid/EV Battery Voltage Sense "A" Circuit, Range/Performance |
| P0B3D00 | Hybrid/high-voltage battery voltage, sensor line 1, short circuit to ground |
| P0B3E00 | Hybrid/high-voltage battery voltage, sensor line 1, short circuit to B+ |
| P0BBD00 | Hybrid Battery Pack Voltage Variation Exceeded Limit |
| P0C3A00 | Control unit – Function limitation |
| P0C3F00 | Control unit – Function limitation |
| P0C4200 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input) – open circuit |
| P0C4300 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input) – signal implausible |
| P0C4400 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input), short circuit to ground |
| P0C4500 | Temperature sensor for low-temperature circuit (TME: TW7 / BMS: HV battery input), short circuit to B+ |
| P0C4700 | Additional coolant pump in low-temperature circuit (P2) – no communication |
| P0C4800 | Additional coolant pump in low-temperature circuit (P2) – PWM signal, short circuit to ground |
| P0C4900 | Additional coolant pump in low-temperature circuit (P2) – PWM signal, short circuit to B+ |
| P0C4A00 | Auxiliary coolant pump in the low-temperature circuit (P2) – error |
| P0C4C00 | Additional coolant pump in low-temperature circuit (P2) – short circuit to ground |
| P0C4D00 | Additional coolant pump in low-temperature circuit (P2) – short circuit to B+ |
| P0C7800 | Hybrid/EV Battery System, Precharge Time Too Long |
| P0CA600 | High-voltage battery – charging current too high |
| P0CA700 | Hybrid Battery Discharging Current High |
| P0CD500 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output) – open circuit |
| P0CD600 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output) – signal implausible |
| P0CD700 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output), short circuit to ground |
| P0CD800 | Temperature sensor for low-temperature circuit (TME: TW8 / BMS: HV battery output), short circuit to B+ |
| P0CEF00 | Temperature sensor for medium-temperature circuit (TW5) – signal implausible |
| P0CFF00 | Additional coolant pump in low-temperature circuit (P2) – stuck |
| P0D1500 | High-voltage charger, high-voltage interlock – open circuit |
| P0D2400 | High-voltage charger – overtemperature |
| P0D5600 | Combination charging socket - electrical fault |
| P0D5700 | Combination charging socket - electrical fault |
| P0D5800 | Combination charging socket – proximity short to ground |
| P0D5900 | Charging socket AC, electrical fault |
| P0D9900 | High-voltage charger, charging socket, temperature sensor 1 – electrical fault |
| P0DAC00 | Hybrid/EV Battery Cell Balancing Circuit "A" |
| P0DAF00 | Hybrid/EV Battery Cell Balancing Circuit "A" Range/Performance |
| P0E2F00 | High Voltage Fuse "B" |
| P0E3000 | High Voltage Fuse "C" |
| P0E3200 | Internal voltage sensor 1 – signal implausible |
| P0E3400 | Internal voltage sensor 2 – signal implausible |
| P0E3700 | Internal voltage sensor 2 – signal implausible |
| P0E3800 | Internal voltage sensor 2 – signal implausible |
| P0E3900 | Internal voltage sensor 2 – signal implausible |
| P0E5200 | DC/DC converter current sensor – signal implausible |
| P0E5300 | DC/DC converter current sensor - short circuit to ground |
| P0E5400 | DC/DC converter current sensor, short circuit to B+ |
| P0E7400 | Hybrid/EV Battery Voltage Internal Isolation Fault |
| P0E9700 | High-voltage voltage converter, voltage sensor, below minimum |
| P0E9800 | High-voltage voltage converter, voltage sensor, below minimum |
| P0E9900 | High-voltage voltage converter, voltage sensor, below minimum |
| P0E9C00 | DC/DC converter, current sensor 2 – signal implausible |
| P0E9D00 | DC/DC converter current sensor 2 - short circuit to ground |
| P0E9E00 | DC/DC converter, current sensor 2 - short circuit to B+ |
| P0EA300 | Control unit – function restriction |
| P160900 | Crash switch-off was triggered |
| P168A00 | Reversible crash shut-off was triggered |
| P1A0100 | Crash signal monitoring, failed |
| P1B1500 | Hybrid battery precharge resistance, Excess temp. |
| P1B1600 | Charging hybrid battery, No external charge detected |
| P1B1B00 | Control unit – function restriction |
| P1B3D00 | Control unit – Function limitation |
| P1CC400 | Control unit - function restriction |
| P1D0100 | Warning: Capacity jump |
| P1D5C00 | Current/voltage sensor defective |
| P1D5F00 | Cell module, state of charge – above limit value |
| P1D6500 | Cell module, state of charge – below limit value |
| P1EF200 | Control unit – Function limitation |
| P1EF300 | Control unit – function restriction |
| P1EF400 | Control unit – function restriction |
| P262B00 | Control Module Power Off Timer Performance |
| P29FF00 | Thermal outlier detected |
| P32B300 | Control unit – Function limitation |
| P33F000 | High-voltage system activation, Malfunction |
| P33F100 | High-voltage system deactivation, Malfunction |
| U002800 | Hybrid CAN bus – faulty |
| U002900 | Hybrid CAN bus - no communication |
| U003700 | Vehicle Communication Bus B |
| U003800 | Private CAN bus, no communication |
| U010000 | Engine electronics (DME) control unit – no communication |
| U010100 | Lost Communication with TCM |
| U011000 | High-voltage power electronics control unit - no communication |
| U011100 | LIN bus, battery sensor - no communication |
| U011200 | High-voltage battery control unit – no communication |
| U011600 | Thermal management control unit - missing message |
| U012100 | Brake electronics (PSM) control unit – no communication |
| U012200 | Brake electronics (PSM) control unit – missing message |
| U014000 | Front-end electronics control unit (BCM1) - missing message |
| U014100 | Front-end electronics control unit (BCM1) - no communication |
| U014600 | Gateway control unit - no communication |
| U014B00 | Gateway – incorrect signal |
| U015100 | Airbag control unit - missing message |
| U015500 | Instrument cluster control unit - missing message |
| U016400 | Air conditioner control unit - missing message |
| U019B00 | High-voltage charger (OBC) control unit – missing message |
| U029800 | Control unit for high-voltage voltage converter (combi converter) - missing message |
| U030000 | Control unit, incorrect coding |
| U033700 | Software Incompatibility with Battery Charger Control Module |
| U033A00 | Software Incompatibility With Hybrid/EV, Battery Interface Control Module "A" |
| U040100 | Engine electronics (DME) control unit – signal implausible |
| U041100 | High-voltage power electronics control unit – signal implausible |
| U041500 | Control unit for brake electronics (PSM) – signal implausible |
| U041600 | Data bus - fault value received |
| U043100 | Data bus - fault value received |
| U044700 | Gateway control unit – signal implausible |
| U045200 | Airbag control unit - signal implausible |
| U045600 | Thermal management control unit - signal implausible |
| U049C00 | High-voltage charger control unit (OBC) - signal implausible |
| U110000 | Component protection – not taught |
| U110100 | Component protection active |
| U110300 | Production mode active |
| U111400 | Component protection – authentication failed (GFA) |
| U111500 | Component protection – not taught (SHE) |
| U113A00 | Charging device for high voltage battery, implausible message |
| U140000 | Function restriction – supply voltage too low |
| U140100 | Function restriction – supply voltage too high |
| U300100 | Control unit – run-on fault |