CodeFault
B139700Function restriction, crash signal
B17FF00High-voltage charger, charging module – sensor fault
B184BF0Temperature sensor, Power reduction due to excessive temperature
B184C00Release active
B191CF8Charge port door – communication error
B191CF9Second plug detected
B191EF0Universal charging cable – fault present
B192BF0High-voltage DC charger (booster) in wrong mode
B192E11Charging socket (AC), searchlight – short circuit to ground
B192E12Charging socket (AC) searchlight – short circuit to B+
B192E13Charging socket (AC) searchlight – open circuit
B193A11High-voltage DC voltage sensor 1, Short circuit to Ground (GND)
B193A12High-voltage DC voltage sensor 1, Short circuit to B+
B193A21High-voltage DC voltage sensor 1, lower limit not reached
B193A22High-voltage DC voltage sensor 1, upper limit exceeded
B193B11High-voltage DC voltage sensor 2, Short circuit to Ground (GND)
B193B12High-voltage DC voltage sensor 2, Short circuit to B+
B193B21High-voltage DC voltage sensor 2, lower limit not reached
B193B22High-voltage DC voltage sensor 2, upper limit exceeded
B194B11Charging socket (DC), searchlight – short circuit to ground
B194B12Charging socket (DC) searchlight – short circuit to B+
B194B13Charging socket (DC) searchlight – open circuit
B1A8101High-voltage AC current sensor, power correction phase 1, Electrical malfunction
B1A8201High-voltage AC current sensor, power correction phase 2, Electrical malfunction
B1A8301High-voltage AC current sensor, power correction phase 3, Electrical malfunction
B1A8401High-voltage output current sensor, Electrical malfunction
B1A8501High-voltage output voltage sensor, Electrical malfunction
B1A8604Charging socket (DC) - function button defective
B1A8704Charging socket (AC) - function button defective
B1A884BActuator for right charging port door - overtemperature
B1A8896Actuator for right charge port door - internal error
B1A88F0Actuator for right charge port door – travel error
B1A88F1Actuator for right charge port door - supply voltage error
B1A88F2Actuator for right charge port door - referencing error
B1A88F3Actuator for right charging port door - communication error
B1A8904Right charge port door LED module – defective
B1A8996LED module on right charge port door, internal error
B1A89F0LED module for right charge port door, communication error
B1A89F1Right charge port door LED module – anti-play prevention active
B1A89F2LED module for right charge port door – overvoltage
B1A89F3LED module for right charge port door – undervoltage
B1A8A4BActuator for left charging port door - overtemperature
B1A8A96Actuator for left charge port door - internal error
B1A8AF0Actuator for left charge port door – travel error
B1A8AF1Actuator for left charge port door - supply voltage error
B1A8AF2Actuator for left charge port door - referencing error
B1A8AF3LIN actuator for charge port door – communication error
B1A8F04LED module for left charge port door – defective
B1A8F96LED module on left charge port door, internal error
B1A8FF0LED module for left charge port door, communication error
B1A8FF1Left charge port door LED module – anti-play prevention active
B1A8FF2LED module for left charge port door – overvoltage
B1A8FF3LED module for left charge port door – undervoltage
B1A9201High-voltage AC current sensor, power correction 2 phase 2, Electrical malfunction
B1A9301High-voltage AC current sensor, power correction 2 phase 3, Electrical malfunction
B1A9401High-voltage AC current sensor, power correction 2 phase 1, Electrical malfunction
B1AA5F0High-voltage charger 2 - component protection active
B1AD100Control unit – function restriction
B1B3804Left charge port door, sensor for contactless opening – defective
B1B38F0Left charge port door, sensor for contactless opening – communication error
B1B38F1Left charge port door, sensor for contactless opening – contamination level exceeded
B1B38F2Left charge port door, sensor for contactless opening, anti-play prevention active
B1B3904Right charge port door, sensor for contactless opening – defective
B1B39F0Right charge port door, sensor for contactless opening – communication error
B1B39F1Right charge port door, sensor for contactless opening – contamination level exceeded
B1B39F2Right charge port door, sensor for contactless opening, anti-play prevention active
B1E31F0Motor locking flap for energy supply, end position detection, implausible value
B200000Control unit – function restriction
B200043Control unit – function restriction
B200100Control unit – wrong software version
B200500Coding
B2009F0Function restriction, temperature - below limit value
B200AF0Function restriction, due to high current cut-out
B201200Coding
B203000Charge module contactless charging – encoding inconsistent
B203400Warning – overtemperature
B2F0100Development code 1
B2F0200Development code 2
B2F0300Development code 3
B2F0500Development code 5
B2F0600Development code 6
B2F0700Development code 7
B2F0800Development code 8
B2F0900Development code 9
B2F0A00Development code 10
B2F0B00Development code 11
B2F0C00Development code 12
B2F0D00Development code 13
C116300Development functions active
C119E00High voltage charger – HV variant coding faulty
C11B896High-voltage charger – internal error
C1249F4Function restriction due to too many wake-up calls from charging infrastructure
C128E00Charging module, non-contact charging – internal error
C1318F2Non-contact high-voltage battery charging module, In incorrect mode
P060B00Control unit – internal error
P061000Control unit - variant coding invalid
P0CA400Hybrid/high-voltage battery – charging voltage too high
P0CA600High-voltage battery – charging current too high
P0D1500High-voltage charger, high-voltage interlock – open circuit
P0D1700High voltage charger, safety line – short circuit to ground
P0D1800High voltage charger, safety line – short circuit to B+
P0D2400High-voltage charger – overtemperature
P0D2700High-voltage charger, line conductor L1 – undervoltage
P0D2800High-voltage charger, line conductor L1 – overvoltage
P0D2A00High-voltage charger – input current too high
P0D5700Combination charging socket - electrical fault
P10BA00Emergency charging function, active
P10BB00Unlocking prohibition - output diagnostic test active
P16EF00High-voltage charger – charging module 3 defective
P16F000High-voltage charger, line conductor L3 – undervoltage
P16F100High-voltage charger, line conductor L3 – overvoltage
P178E00Compressor for level control, Temperature too high
P195B00Pre-warning insufficient temperature
P1A1500Charging unit 2, Function restriction
P1A2400Fast battery charge (DC), CHAdeMO connector – implausible signal
P1A3500Quick battery charging (DC), Malfunction in charging station
P1B2C00AC charging socket – function restriction due to overtemperature
P1BC900Intermediate circuit input voltage sensor 1, Electrical malfunction
P1BCA00Intermediate circuit input voltage sensor 2, Electrical malfunction
P1BCC00External charging infrastructure – fault in line conductor L2 and L3
P1BCD00External charging infrastructure – fault in line conductor L1 and L3
P1BCE00External charging infrastructure – fault in line conductor L1 and L2
P1DE600DC charging socket, communication line, implausible signal
P31C500Reduced performance due to excessive coolant temperature
P31C600AC input voltage – electrical system fault
P31C700Charging socket AC, AC electrical system supply – open circuit
P31C800Combination charging socket, AC electrical system supply – open circuit
P31C900LED module charging socket A, Electrical error
P31CB00Immediate upload button, sticks closed
P31CC00Button for loading profile, sticks closed
P31CD00AC charge port door locking activation, electrical fault
P31CE00Combination charge port door locking activation, electrical fault
P31CF00Charging-socket lid A, locking detection, electrical fault
P31D000Charging-socket lid B, locking detection, electrical fault
P31D100Charging socket - temperature sensor, electrical fault
P31D200Charging socket - overtemperature
P31D500Charging socket AC, plug lock detection - electrical fault
P31D600Combination charging socket plug lock detection - electrical fault
P31D700Charging socket AC, communication connection - short circuit to B+
P31D800Combination charging socket, communication connection - short circuit to B+
P31D900High-voltage charger, high-voltage output – short circuit
P31DA00Button 1 LED, Electrical error
P31DB00Button 2 LED, Electrical error
P31DC00Search illumin. for button module, Electrical error
P31DD00Charging socket AC, plug lock activation - electrical fault
P31DE00Combination charging socket, plug lock activation - electrical fault
P31DF00Charging socket AC, communication connection - short circuit to ground
P31E100CHAdeMO charging socket – electrical fault
P31E200Charging socket A, AC electrical system supply – short circuit
P31E400Immediate upload button, Open circuit
P31E500Button for loading profile, Open circuit
P31E700AC electrical system supply line – open circuit
P31E900High-voltage charger – charging module 1 defective
P31EA00High-voltage charger – charging module 2 defective
P31EB00High-voltage charger, line conductor L2 – undervoltage
P31EC00High-voltage charger, line conductor L2 – overvoltage
P31EF00Line conductor energy throughput – difference too high
P31F000Switch-off due to coolant overtemperature
P33DC00Hybrid/high-voltage battery – charging voltage too low
P33DD00High-voltage battery – setpoint voltage exceeded
P33DE00Rated current request of high-voltage battery, too high
P33DF00High-voltage charger, line conductor – setpoint current requirement too low
P33E000High-voltage charger, line conductor - required/actual current difference too high
P33E100Charging socket AC, electrical fault
P33E200Combination charging socket - electrical fault
P33E300Charging socket AC, communication error
P33E400Combination charging socket, communication error
P33E500Quick battery charging (DC), Charge stn., initialization error
P33E600Charging socket AC charging-plug lock, short circuit to ground
P33E700Combination charging socket charging-plug lock, short circuit to ground
P33E800Charging socket AC charging-plug lock, mechanical fault
P33E900Combination charging socket charging-plug lock, mechanical fault
P33EA00High-voltage battery charging – fault in vehicle high-voltage system
P33EB00High-voltage battery management system – fault memory entry available
P33EC00AC charging socket proximity switch – electrical fault
P33ED00Combination charging socket – proximity short to ground
P33EF00A/C not possible, Charge state too low
P33F000High-voltage system activation, Malfunction
P33F100High-voltage system deactivation, Malfunction
U000200High Speed CAN Communication Bus, Performance
U002800Hybrid CAN bus – faulty
U002900Hybrid CAN bus - no communication
U030000Control unit, incorrect coding
U033700Software Incompatibility with Battery Charger Control Module
U101100Supply voltage – too low
U101200Supply voltage – too high
U101300Coding
U102500Air conditioning control unit – fault memory entry available
U103000LIN bus 1 – electrical fault
U110000Component protection – not taught
U110100Component protection active
U110300Production mode active
U111100Operating and display log - missing message
U111400Component protection – authentication failed (GFA)
U111500Component protection – not taught (SHE)
U111600Subnetwork operation not available
U112100Data bus - missing message
U112200Data bus - implausible message
U112300Data bus – fault value received
U120000Data bus, Faulty
U13AE00Active parking system control unit – fault detected
U140000Function restriction – supply voltage too low
U140100Function restriction – supply voltage too high
U140900Internal temperature measurement, Implausible signal
U14CA00External charging infrastructure – infrastructure does not support vehicle communication protocol
U152200High-voltage charger, Plug and Charge function – communication from backend implausible
U153100Internal temperature measurement, Implausible signal
U15A900Intelligent charging function, Function restriction
U15AA00Rapid battery charging (DC) – electrical fault in charging station
U15AB00Quick battery charging (DC), Communication error between vehicle and charging station
U15AC00Signal damping log, Malfunction
U15AD00Quick battery charging (DC), Charging station incompatible
U15AE00Quick battery charging (DC), Charging station communication failure
U15AF00Quick battery charging (DC), Charging station encoding failed
U15B000Rapid battery charging (DC) – fault in locking the charging cable
U15B100Rapid battery charging (DC), error in application log
U15B200Quick battery charging (DC), Energy transfer type error
U15B300Fast battery charge (DC) – cable testing error
U15B500Quick battery charging (DC), Charging station not active
U15BF00Intelligente Ladefunktion, fehlerhafte Kommunikation
U15C800Rapid battery charging (DC), PowerLine communication, error in certificate
U15C900Safety module (FuSi), Function override
U167300High voltage charger, plug and charge function, communication error between vehicle and charging station
U16D300High voltage charger, pre-charging not successful
U16D400High voltage battery charger, plug and charge function – backend error
U16D600High voltage battery charger, plug and charge function – charger error
U19B000Left charging port door, LED module, temporary restriction
U19B100Right charging port door, LED module, temporary restriction
U300100Control unit – run-on fault

Fault names come from the manufacturer's diagnostic data. STEUER14 is independent and not affiliated with Porsche AG. A code tells you what a control unit detected, not always which part failed — check wiring, supply voltage and related codes before replacing parts. STEUER14 shows each fault's full description, status and freeze frame on the car.